View Issue Details

IDProjectCategoryView StatusLast Update
0000976T99X171.00 SKB EagleSW Issuepublic2021-12-23 17:23
Reporter(ALTech) Jason ParkAssigned To(SW) Kerwin Chen Due Date
PrioritynormalSeveritys2-severeReproducibilityhave not tried
Status closedResolutionopen 
Summary0000976: [BTF] When enter RCU ota mode, as piled key, it was proceed at once and it is working as IR after a while.
Descriptionhi kerwin

 we tested with v15.522.4a. it seem didn't reproduce hang-up issue(don't working RCU). But as piled key , it was proceed at once and it is working as IR after a while.

 log(Logcat) : https://drive.google.com/file/d/1WJ6RCghhbDpx5K0exA8nwwNIWKcW6QK0/view?usp=sharing
 log(btsnoop) : https://drive.google.com/file/d/1fgYlehsCeTuwz-tFQk46RVGqF1gFSugA/view?usp=sharing

Thanks.
TagsNo tags attached.
Attach Tags

Relationships

related to 0000859 closed(SW) Kerwin Chen [BFX_AT100][BTVQ-13671] After enter OTA mode, didn't work BackKEY. 

Users monitoring this issue

Activities

(SW) Kerwin Chen

2020-10-07 09:56

developer   ~0004541

Hi Jason,

Could you describe issue more detail?
I check the log file, there are many times of RCU OTA rnning.
I don't understand your description about "But as piled key , it was proceed at once and it is working as IR after a while" .

==================== logcat_RCU_OTA.log =====================
...
10-05 15:11:45.016 4910 4910 D OTA : APPLICATION_ID=com.realsil.sdk.dfu
...
10-05 15:12:01.578 4910 4910 D OTA : APPLICATION_ID=com.realsil.sdk.dfu
...
10-05 15:12:18.489 4910 4910 D OTA : APPLICATION_ID=com.realsil.sdk.dfu
...
10-05 15:12:28.962 4910 4910 D OTA : APPLICATION_ID=com.realsil.sdk.dfu
...
10-05 15:13:47.083 4910 4910 D OTA : APPLICATION_ID=com.realsil.sdk.dfu
...
10-05 15:14:01.824 4910 4910 D OTA : APPLICATION_ID=com.realsil.sdk.dfu
...
10-05 15:14:19.035 4910 4910 D OTA : APPLICATION_ID=com.realsil.sdk.dfu
...
10-05 15:14:32.155 4910 4910 D OTA : APPLICATION_ID=com.realsil.sdk.dfu
...
10-05 15:14:51.744 4910 4910 D OTA : APPLICATION_ID=com.realsil.sdk.dfu
...
10-05 15:15:05.090 4910 4910 D OTA : APPLICATION_ID=com.realsil.sdk.dfu
...

(ALTech) Jason Park

2020-10-12 14:30

developer   ~0004587

Last edited: 2020-10-12 14:31

hi kerwin

"But as piled key , it was proceed at once and it is working as IR after a while
this mean is it is working as like Mantis-841.
https://mantis.cnsbg.foxconn.com/vaas/view.php?id=841

key is proceed at once and It seem BT is disconnected and it working as IR.

Issue History

Date Modified Username Field Change
2020-10-06 13:51 (ALTech) Jason Park New Issue
2020-10-06 13:52 (ALTech) Jason Park Assigned To => (SW) Kerwin Chen
2020-10-06 13:52 (ALTech) Jason Park Status new => assigned
2020-10-06 13:52 (ALTech) Jason Park Relationship added related to 0000859
2020-10-06 13:52 (ALTech) Jason Park Issue Monitored: (ALTech) Wooshin Kang
2020-10-06 13:52 (ALTech) Jason Park Issue Monitored: (ALTech) SY Yoon
2020-10-07 09:56 (SW) Kerwin Chen Note Added: 0004541
2020-10-07 09:56 (SW) Kerwin Chen Assigned To (SW) Kerwin Chen => (ALTech) Jason Park
2020-10-07 09:56 (SW) Kerwin Chen Status assigned => feedback
2020-10-12 14:30 (ALTech) Jason Park Note Added: 0004587
2020-10-12 14:31 (ALTech) Jason Park Note Edited: 0004587
2020-10-12 14:31 (ALTech) Jason Park Assigned To (ALTech) Jason Park => (SW) Kerwin Chen
2020-10-12 14:31 (ALTech) Jason Park Status feedback => assigned
2021-12-23 17:23 (SW) Jacky Chiang Status assigned => closed